CFS_Ex2 — QA annex

Design-process records supporting Section 7 of the report. Not part of the calculation package.

Source verification

Whether the governing provisions of each standard the systems require were verified against the text of the standard. Light-frame walls (R = 4.0): AISI S100 and S240 are required, and S400 for the seismic system (wind shear walls: S240 B5).

Standard and scopeAppliesEvidenceStatus
AISI S100 — member/connection limit states (effective width method)required0 provision checks + cited in the calculation packageverified
AISI S240 — framing rules (studs/track/built-up/bracing/trusses)required0 provision checks + cited in the calculation packageverified
AISI S400 — seismic wall/strap/SBMF capacities + capacity designrequired0 provision checks + capacity-design record + cited in the calculation packageverified
Connections verified (S100 Ch. J / fastener schedules)requiredconnection designs present / wall fastener schedules filledverified

Every standard the systems require was verified (provision checks or calculation-package citations, above).

Analysis screening notes

Screens the analysis raises for the engineer to evaluate; the evaluation recorded in the calculation package follows each group.

Wall-line forces: semi-rigid / rigid model vs tributary distribution

Evaluation: The floor diaphragms are not flexible (ASCE 7-22 12.3.1), so the wall-line shears are taken from the semi-rigid analysis, in which the lines are coupled through the diaphragm shear stiffness and share the storey shear by relative stiffness. The differences from the flexible tributary distribution are the expected result of that coupling; every wall line, chord, tie-down and anchorage is designed for the analysis shears, and the capacity-design level is taken from the larger of the analysis and tributary shears.

Design log

Analysis runs, self-consistency checks and code-provision checks recorded while this design was prepared. A check that returned no clause from the reference library of standards is listed as “clause not found in the reference library”.

ActivityCount
analysis / check run16
design started1

Chronological record

#timeactivitydetailresult
112:59:16design starteddesign startedcompleted
212:59:31analysis / check runanalysis runcompleted
312:59:49analysis / check runanalysis model, demand envelope and reportcompleted
412:59:49analysis / check runanalysis runcompleted
512:59:54analysis / check runreport renderingcompleted
612:59:55analysis / check runanalysis runreturned an error
713:00:21analysis / check runanalysis model, demand envelope and reportcompleted
813:00:22analysis / check runanalysis runcompleted
913:00:27analysis / check runreport renderingcompleted
1013:01:56analysis / check runanalysis runcompleted
1113:05:53analysis / check runanalysis runcompleted
1217:46:56analysis / check runanalysis model, demand envelope and reportcompleted
1317:46:56analysis / check runanalysis runcompleted
1417:46:59analysis / check runreport renderingcompleted
1517:48:49analysis / check runanalysis runcompleted
1618:42:59analysis / check runanalysis model, demand envelope and reportcompleted
1718:43:00analysis / check runanalysis runcompleted